Results 1 - 20 de 26
Filter
1.
Dental press j. orthod. (Impr.) ; 20(3): 96-100, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-751409

ABSTRACT

OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60) (20 KGy) gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination), Group 2 (70°GL alcohol), Group 3 (autoclave), Group 4 (ultraviolet), Group 5 (peracetic acid) and Group 6 (glutaraldehyde). After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL), and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05). CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties. .


OBJETIVO: verificar os efeitos de diferentes métodos de esterilização/desinfecção nas propriedades mecânicas de elásticos ortodônticos em cadeia. MÉTODOS: segmentos de elástico em cadeia com 5 elos cada foram enviados para esterilização em radiação gama com cobalto 60 (20 KGy). Após esterilização, esses foram contaminados com amostras clínicas de Streptococcus mutans. Passado esse período, foram submetidos aos testes de esterilização/desinfecção por diferentes métodos, formando seis grupos de estudo, assim denominados: Grupo 1 (controle - sem ter sido contaminado), Grupo 2 (álcool 70°GL), Grupo 3 (autoclave), Grupo 4 (ultravioleta), Grupo 5 (ácido peracético) e Grupo 6 (glutaraldeído). Após esterilização/desinfecção, avaliou-se a efetividade desses métodos, por meio de contagem de unidades formadoras de colônias por mL (UFC/mL), e as propriedades mecânicas desses materiais. Utilizou-se o teste t de Student para avaliar o número de UFC, além do ANOVA e, posteriormente, do teste de Tukey para avaliação da força. RESULTADOS: verificou-se que o ultravioleta não obteve eficácia total quanto à esterilização. E não ocorreu perda das propriedades mecânicas dos elásticos, com os diferentes métodos de esterilização utilizados (p > 0,05). CONCLUSÃO: o controle biológico de elásticos em cadeia não interfere nas suas propriedades mecânicas. .


Subject(s)
Humans , Orthodontic Appliances/microbiology , Sterilization/methods , Elastomers/chemistry , Dental Materials/chemistry , Peracetic Acid/therapeutic use , Streptococcus mutans/drug effects , Streptococcus mutans/radiation effects , Stress, Mechanical , Time Factors , Ultraviolet Rays , Materials Testing , Disinfection/methods , Glutaral/therapeutic use , Cobalt Radioisotopes/therapeutic use , Dental Disinfectants/therapeutic use , Radiopharmaceuticals/therapeutic use , Elastomers/radiation effects , Dental Materials/radiation effects , Ethanol/therapeutic use , Elasticity , Bacterial Load/drug effects , Bacterial Load/radiation effects , Gamma Rays/therapeutic use , Hot Temperature
2.
J. appl. oral sci ; 20(5): 588-593, Sept.-Oct. 2012. ilus, tab
Article in English | LILACS | ID: lil-654926

ABSTRACT

The type IV dental stone is widely used for the fabrication of dyes and master casts for fixed and removable partial prostheses. It is typically normal to wait at least 24 hours for the casts to dry prior to beginning the laboratory procedures. The waiting time has been shown to be greatly reduced by using microwave drying. OBJECTIVE: This study evaluated the influence of drying techniques at room temperature and microwave oven on the linear dimensional change, compressive strength and detail reproduction in type IV dental stones. MATERIAL AND METHODS: Three type IV dental stone brands were selected; elite Rock, Shera Premium and Durone IV. Two different drying protocols were tested in 4 groups (n=10); G1 - room temperature (25±4ºC) dried for 2 hours; G2 - room temperature dried for 24 hours; G3 - room temperature dried for 7 days and G4 - microwave oven dried at 800 W for 5 minutes and after 2 hours at room temperature. After drying, the samples were assayed for dimensional charges. The sample surface was submitted to the ImageTool 3.0 software for compressive strength in a universal testing machine with a cell load of 50 KN at a crosshead speed of 0.5 mm/minutes and the detail reproduction was analyzed with a stereomicroscope at 25x magnification. The statistical analysis of the linear dimensional change and compressive strength data were conducted by the ANOVA test followed by the Tukey test (p<0.05). Detailed reproduction values were reported in percentages. RESULTS: For the compressive strength test, Elite Rock and Durone IV did not present significant differences between G2 and G4, while Shera Premium did not present differences between G3 and G4. The best reproduction levels were observed for G3. CONCLUSIONS: Dental stone microwave oven drying showed a linear dimensional change similar to after room temperature drying for 24 hours and 7 days. The compressive strength of the stone dried in the microwave oven was similar to those dried at room temperature for 24 hours, with the exception of Shera Premium, which had similar results for microwave and room temperature drying for 7 days. For the microwave drying method the detail reproduction levels for samples dried at room temperature for 24 hours and 7 days were similar, except for the Durone IV.


Subject(s)
Humans , Dental Casting Technique , Models, Dental , Dental Materials/radiation effects , Microwaves , Temperature , Analysis of Variance , Compressive Strength , Dental Materials/chemistry , Hardness , Materials Testing , Reproducibility of Results , Surface Properties , Time Factors
3.
Article in English | IMSEAR | ID: sea-141243

ABSTRACT

Objective: To determine the effect of delayed light polymerization of a dual-cured composite base material on the marginal adaptation of class II composite restoration. Materials and Methods: 35 extracted human molar teeth were used to prepare class II mesio-occlusal or disto-occlusal slot preparations with gingival margins at the CEJ. The teeth were restored using an open-sandwich technique with a 2mm base increment of dual-cured composite, and divided into 5 groups based on the mode of the polymerization of the dual-cured composite base: Group A - self-cured after placement (5 mins), Group B - light-cured immediately after placement, Group C - light-cured 30 seconds after placement, Group D - light-cured 60 seconds after placement, Group E - light-cured 120 seconds after placement. Then a top layer of a light-cured composite resin is placed to complete the restoration. The teeth were thermocycled and immersed in 1% aqueous solution of methylene blue for 24 hours. Sectioning of the teeth and scoring under stereomicroscope was done. Data will be statistically evaluated using the kruskal wallis 1-way ANOVA. Results: Statistical analysis using kruskal wallis 1-way ANOVA showed that the dual-cured composite light polymerized 1 minute after placement exhibited the least microleakage. Conclusion: Delayed light polymerization of the dual-cured composite base reduced the microleakage in class II open-sandwich restorations.


Subject(s)
Coloring Agents/diagnosis , Composite Resins/chemistry , Composite Resins/radiation effects , Dental Bonding/methods , Dental Cavity Preparation/classification , Dental Leakage/classification , Dental Marginal Adaptation , Dental Materials/chemistry , Dental Materials/radiation effects , Dental Restoration, Permanent/classification , Dental Restoration, Permanent/methods , Dentin-Bonding Agents/chemistry , Humans , Humidity , Light-Curing of Dental Adhesives/methods , Materials Testing , Methylene Blue/diagnosis , Polymerization , Self-Curing of Dental Resins/methods , Temperature , Time Factors , Tooth Cervix/pathology
4.
Braz. dent. j ; 22(5): 388-391, 2011. ilus, tab
Article in English | LILACS | ID: lil-601839

ABSTRACT

This in vitro study evaluated the temperature of dentures after different microwave irradiation protocols. Two complete dentures (one maxillary and one mandibular denture) were irradiated separately 4 times for each of the following 5 protocols: dentures immersed in water (G1- 6 min, G2- 3 min); dentures kept dry (G3- 6 min); dentures placed in the steam sterilizer (G4- 6 min, G5- 3 min). The final temperature of the dentures was gauged in a thin and in a thick area of each denture with an infrared thermometer. All groups presented an increase in the resin base temperature. The thin areas of the dentures underwent greater heating than the thick areas. There was no significant difference (p>0.05) between the final mean temperatures of dentures immersed in water for 6 (G1) and 3 min (G2). However, the final mean temperatures recorded in G1 and G2 exceeded 71°C and were significantly higher (<0.001) than the final mean temperatures recorded in the other groups. It may be concluded that denture base resins subjected to microwave irradiation immersed in water may be exposed to deleterious temperatures.


Este estudo in vitro avaliou a temperatura de próteses submetidas a diferentes protocolos de irradiação de microondas. Duas próteses totais (uma superior e outra inferior) foram irradiadas separadamente quatro vezes para cada um dos 5 protocolos que se seguem: prótese imersas em água (G1- 6 min, G2- 3 min); prótese a seco (G3-6 min); prótese no vapor (G4- 6 min, G5- 3 min). A temperatura final das próteses foi aferida em uma área fina e uma área espessa de cada prótese com um termômetro de infravermelho. Os resultados mostraram que todos os grupos sofreram aumento de temperatura. As áreas finas da prótese tiveram mais aumento da temperatura que as áreas espessas. Não houve uma diferença estatisticamente significante (p>0,05) entre a média da temperatura final das próteses imersas em água por 6 (G1) e 3 min (G2). Entretanto, a temperatura final média observada no G1 e G2 excederam 71o C e foram significativamente maiores (p<0,001) que a temperatura final média dos outros grupos. Pode-se concluir que as bases de prótese submetidas à irradiação por microondas imersas em água podem estar expostas a temperaturas deletérias.


Subject(s)
Humans , Acrylic Resins/chemistry , Denture Bases , Dental Materials/chemistry , Microwaves , Acrylic Resins/radiation effects , Denture, Complete, Lower , Denture, Complete, Upper , Dental Materials/radiation effects , Hot Temperature , Immersion , Materials Testing , Radiation Dosage , Steam , Sterilization/instrumentation , Sterilization/methods , Temperature , Thermometers , Water/chemistry
5.
JCPSP-Journal of the College of Physicians and Surgeons Pakistan. 2011; 21 (7): 411-414
in English | IMEMR | ID: emr-129784

ABSTRACT

To determine the microhardness and depth of cure of nanocomposite using different irradiation times on both upper and lower surfaces of composite material. In-vitro experimental study design. Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences and NED University of Engineering and Technology, Karachi, from March to May 2010. Total 120 cylinder shaped specimens; 60 specimens for depth of cure test and 60 specimens for micro hardness test were fabricated using A3 shade of nanocomposite [Filtek Z350 XT, 3M ESPE]. For each irradiation time four groups were made [Group 1 = 20s] [Group 2 = 30s], [Group 3 = 40s] and [Group 4 = 60s]. For each group fifteen specimens were used. The resin was placed and polymerized into a cylindrical plastic mold. Depth of cure was measured by using micrometer. Micro Vickers hardness was measured on both top and bottom surfaces. SPSS-16.0 was used for statistical analysis. There was statistically significant difference in the depth of cure between all groups showing the highest value in group 4 [p < 0.001]. For hardness on top surface, there was a statistically significant difference in between groups 1 and 2 [p=0.001], groups 1 and 3 [p < 0.001], groups 1 and 4 [p < 0.001] There was no statistically significant difference between groups 2 and 3, groups 2 and 4 and in between groups 3 and 4. For hardness on bottom surface, there was statistically significant difference in between all groups showing the highest value in group 4 [p < 0.001]. Depth of cure and hardness was increased by increasing irradiation time. Hardness on the top surface was higher than bottom surface values


Subject(s)
Humans , Dental Materials/radiation effects , Light , Nanocomposites , Materials Testing/methods , Surface Properties , Composite Resins/standards , Hardness , Hardness Tests , Time Factors
6.
Braz. j. oral sci ; 9(3): 384-387, July-Sept. 2010. ilus, tab
Article in English | LILACS, BBO | ID: lil-578066

ABSTRACT

Aim: This study investigated the tooth movement of complete dentures processed by micro wave activation and conventional processing method in water bath. Methods: Twenty maxillary complete dentures were fabricated and randomly assigned to 4 groups (n=5): Group I: Classico convention alheat-curing acrylic resin processed by microwave polymerization; Group II: Classico resinprocessed in water bath at 74°C for 9 h (control-group); Group III: QC-20 fast heat-curing acrylic resin processed in boiling water for 20 min; Group IV: Onda-Cryl microwave acrylic resin processed at the same conditions of Group 1. Metallic referential pins were placed on the incisal border of the central incisors, buccal cusp of the first premolars, and the mesiobuccal cusp of the second molars.Transversal and anteroposterior distances were measured before and after the complete dentures processing with a linear optical microscope (Olympus Optical Co., Tokyo, Japan) accurate to0.0005 mm. Data were subjected to A NOVA and Tukey’s test at 5% significance levels. Results:Inside each group, dentures showed some tooth movement but without statistical difference before and after the polymerization. Conclusions: Dentures processed by microwave energy presented similar performance to those subjected to conventional cycles in water bath for most of distances evaluated.


Subject(s)
Acrylic Resins/chemistry , Denture, Complete , Dental Materials/chemistry , Microwaves , Tooth Movement Techniques , Analysis of Variance , Acrylic Resins/radiation effects , Denture Bases , Dental Materials/radiation effects , Materials Testing , Time Factors , Tooth, Artificial , Water/chemistry
7.
Article in English | IMSEAR | ID: sea-139888

ABSTRACT

Background : Though acrylic resins possess many desirable properties, denture fracture due to flexural fatigue or impact failure is a common problem. One major factor influencing the flexural fatigue strength of denture base resins is the processing technique used. Aim: To measure the flexural fatigue strength of denture base resins polymerized using short and long curing cycles using water bath, pressure cooker, and microwave polymerization techniques. Materials and Methods: Flexural fatigue strength of 60 samples (n=10) were measured using a cyclic 3-point loading method on a dynamic universal testing machine. Data were analyzed using a Student 't' test. Results : Comparative evaluation using Student's 't' test of mean flexural fatigue strength of samples processed by water bath processing (660.6) and the microwave technique (893.6) showed statistically significant (P <0.01) result with microwave processing being higher. Comparison of water bath (660.6) and pressure cooker (740.6) processing and microwave (893.6) and pressure cooker (740.6) processing using Student's 't' test was not statistically significant (P >0.05). In the intra-group analysis, it was found that there was statistically significant difference in samples processed using the short and long curing cycle, the latter being better in all groups, P-values being <0.05, <0.001, and <0.001 for water bath, microwave, and pressure cooker polymerization techniques, respectively. Conclusion : The polymerization procedure plays an important role in influencing the flexural fatigue strength of denture base resins, and the microwave long curing processing technique produced denture bases with highest flexural fatigue strength.


Subject(s)
Acrylic Resins/chemistry , Acrylic Resins/radiation effects , Dental Materials/chemistry , Dental Materials/radiation effects , Dental Stress Analysis/instrumentation , Denture Bases , Elastic Modulus , Humans , Materials Testing , Methylmethacrylate/chemistry , Methylmethacrylate/radiation effects , Microwaves , Pliability , Polymerization , Polymethyl Methacrylate/chemistry , Polymethyl Methacrylate/radiation effects , Pressure , Stress, Mechanical , Time Factors , Water/chemistry
8.
J. appl. oral sci ; 18(1): 59-67, Jan.-Feb. 2010. tab, ilus
Article in English | LILACS | ID: lil-545028

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the effect of different filler sizes and shapes on the surface roughness of experimental resin-composite series. MATERIAL AND METHODS: Thirty-three disc-shaped specimens of the series (Spherical-RZD 102, 105, 106, 107, 114 and Irregular-RZD 103, 108, 109, 110, 111, 112) were prepared in a split Teflon mold and irradiated with an halogen light-curing unit (450 mW/cm² for 40 s) at both top and bottom surfaces. The specimens were stored for 3 months in distilled water. The surface roughness values in form of surface finish-vertical parameter (Ra), maximum roughness depth (Rmax) and horizontal roughness parameter (Sm) were recorded using a contact profilometer. The data were analyzed by one-way ANOVA and the means were compared by Scheffé post-hoc test (a=0.05). RESULTS: The lowest surface roughness (Ra) was observed in S-100 (0.079±0.013), while the roughest surface was noted in I-450/700/1000 (0.125±0.011) and I-450/1000 (0.124±0.004). The spherical-shape series showed the smoothest surface finish compared to the irregular-shape ones with higher significant difference (p>0.05). The vertical surface roughness parameter (Ra) values increased as the filler size increased yielding a linear relation (r²=0.82). On the contrary, the horizontal parameter (Sm) was not significantly affected by the filler size (r²=0.24) as well as the filler shape. CONCLUSIONS: Filler particle's size and shape have a great effect on the surface roughness parameters of these composite series.


Subject(s)
Humans , Composite Resins/chemistry , Dental Materials/chemistry , Aluminum Oxide/chemistry , Barium Compounds/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Carbon Compounds, Inorganic/chemistry , Composite Resins/radiation effects , Curing Lights, Dental/classification , Dental Materials/radiation effects , Dental Polishing/methods , Glass/chemistry , Materials Testing , Methacrylates/chemistry , Nanocomposites/chemistry , Particle Size , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Polyurethanes/chemistry , Surface Properties , Silanes/chemistry , Silicon Compounds/chemistry , Silicon Dioxide/chemistry , Time Factors , Water/chemistry
9.
Braz. dent. j ; 21(4): 346-350, 2010. graf
Article in English | LILACS | ID: lil-562097

ABSTRACT

The aim of this study was to examine Streptococcus mutans biofilm growth on both aged and non-aged restorative dental resins, which were submitted to therapeutic irradiation. Sixty-four disks of an esthetic restorative material (Filtek Supreme) were divided into 2 groups: aged group (AG) and a non-aged group (NAG). Each group was subdivided into 4 subgroups: non-irradiated and irradiated with 10Gy, 35Gy, and 70Gy. The biofilms were produced by Streptococcus mutans UA159 growing on both AG and NAG surfaces. The colony-forming units per mL (CFU/mL) were evaluated by the ANOVA and the Tukey LSD tests (α=0.05). AG presented smaller amounts of CFU/mL than the NAG before irradiation and after 10Gy of irradiation (p<0.05). AG irradiated with 35 and 70Gy showed increased amount of bacterial biofilm when compared to non-irradiated and 10Gy-irradiated disks (p<0.05). The exposure to ionizing radiation at therapeutic doses promoted changes in bacterial adherence of aged dental restorative material.


O objetivo deste estudo foi avaliar a formação do biofilme de Streptococcus mutans crescido em resina restauradora envelhecida e não-envelhecida, submetidas à radiação terapêutica. Sessenta e quatro discos do material restaurador Filtek Supreme foram divididos em 2 grupos: grupo envelhecido (AG) e grupo não-envelhecido (NAG) e cada grupo foi dividido em 4 sub-grupos: não-irradiado e irradiado com 10Gy, 35Gy e 70Gy. O biofilme de S. mutans UA159 foi produzido na superfície de ambos os discos AG e NAG. As unidades formadoras de colônia/mL (UFC/mL) foram avaliadas por ANOVA e teste de Tukey (α=0,05). O grupo AG demonstrou menores quantidades de UFC/mL que o grupo NAG antes da radiação e após a radiação de 10Gy (p<0,05). Os sub-grupos AG irradiados com 35 e 70Gy demonstraram aumento na quantidade de biofilme quando comparado aos não irradiados e irradiados com 10Gy (p<0,05). A exposição à radiação ionizante nas doses terapêuticas promoveu mudanças na aderência bacteriana no material restaurador.


Subject(s)
Bacterial Adhesion/radiation effects , Composite Resins/radiation effects , Dental Pellicle/radiation effects , Radiotherapy , Streptococcus mutans/radiation effects , Analysis of Variance , Biofilms/radiation effects , Dose-Response Relationship, Radiation , Dental Materials/radiation effects , Dental Pellicle/microbiology , Dental Restoration, Permanent/methods , Light-Curing of Dental Adhesives , Statistics, Nonparametric , Time Factors
10.
Braz. oral res ; 23(4): 467-472, Oct.-Dec. 2009. ilus, tab
Article in English | LILACS | ID: lil-534219

ABSTRACT

This study analyzed the influence of polymerization cycle and post-pressing time on tooth movement in complete dentures. Forty maxillary complete dentures were fabricated and randomly assigned to 8 groups (n = 5); the polymerization cycle (conventional long cycle in water bath, fast cycle in boiling water, and by microwave energy) and the post-pressing time (immediate and 6 hours) were varied. Metal reference pins were placed on the incisal border of the central incisors (RI and LI), on the buccal cusp of the first premolars (RP and LP), and on the mesiobuccal cusp of the second molars (RM and LM). Two transverse and 2 anteroposterior distances were measured with a linear optical microscope (Olympus Optical Co., Tokyo, Japan) with an accuracy of .0005 mm, before and after processing the complete dentures. The data collected were submitted to analysis of variance (ANOVA) and the Tukey Test at a significance level of 5 percent. When Clássico, a conventional heat-polymerizable acrylic resin, was polymerized by microwave energy, tooth movement was statistically significant for 2 distances, with the highest value being observed for the 6-hour post-pressing time. Onda-Cryl microwave acrylic resin processed by microwave energy presented the lowest tooth movement for 2 distances, considering the 6-hour post-pressing time. QC-20 acrylic resin presented no statistically significant change considering both post-pressing times in each distance evaluated. Tooth movement showed an asymmetric behavior, so the mastering of the processing method is essential to the precise execution of all laboratory steps, irrespective of the polymerization cycle and post-pressing time used.


Subject(s)
Acrylic Resins/chemistry , Dental Casting Technique , Denture, Complete , Dental Materials/radiation effects , Polymers/chemistry , Analysis of Variance , Dental Materials/chemistry , Materials Testing , Microwaves , Surface Properties , Time Factors , Tooth Movement Techniques , Tooth, Artificial
11.
J. appl. oral sci ; 17(6): 617-622, Nov.-Dec. 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-534430

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the Vickers hardness number (VHN) and the in vitro marginal adaptation of inlay restorations of three hybrid composite resins (Filtek Z250, Opallis and Esthet-X) subjected to two post-cure treatments. MATERIAL AND METHODS: For the microhardness test, three different groups were prepared in accordance with the post-cure treatments: control group (only light cure for 40 s), autoclave group (light cure for 40 s + autoclave for 15 min at 130ºC); and microwave group (light cure for 40 s + microwave for 3 min at 450 W). To assess the marginal adaptation, the composite resin was inserted incrementally into a mesial-occlusal-distal cavity brass mold and each increment light-cured for 40 s. A previous reading in micrometers was taken at the cervical wall, using a stereomicroscope magnifying glass equipped with a digital video camera and image-analysis software. Subsequently, the specimens were subjected to the post-cure treatments (autoclave and microwave) and a reading was taken again at the cervical wall. Data were compared using ANOVA for the hardness test, split-plot ANOVA for the adaptation assessment and Tukey's test for multiple comparisons. A significance level of 5 percent was adopted for all analyses. RESULTS: The post-cure treatments increased the hardness of conventional composites (p<0.001) and the gap values of inlay restorations (p<0.01). Filtek Z250 showed higher hardness (p<0.001) and lower gap values than Opallis and Esthet-X (p<0.05). Gap values did not exceed 90 µm for any of the experimental conditions. CONCLUSION: The post-cure treatments increased the VHN and the gap values on the cervical floor of composite resin inlays. Moreover, Filtek Z250 showed the best results, with higher hardness and lower gap values.


Subject(s)
Humans , Composite Resins/chemistry , Dental Marginal Adaptation , Dental Materials/chemistry , Inlays , Bisphenol A-Glycidyl Methacrylate/chemistry , Bisphenol A-Glycidyl Methacrylate/radiation effects , Composite Resins/radiation effects , Dental Polishing , Dental Materials/radiation effects , Hardness , Hot Temperature , Image Processing, Computer-Assisted , Light , Materials Testing , Microwaves , Methacrylates/chemistry , Methacrylates/radiation effects , Polyethylene Glycols/chemistry , Polyethylene Glycols/radiation effects , Polymethacrylic Acids/chemistry , Polymethacrylic Acids/radiation effects , Surface Properties , Time Factors , Video Recording , Water/chemistry
12.
J. appl. oral sci ; 17(5): 432-435, Sept.-Oct. 2009. graf
Article in English | LILACS | ID: lil-531392

ABSTRACT

OBJECTIVE: The presence of Candida albicans on the surfaces of denture-base acrylic resins is strongly related to the development of oral stomatitis. This study evaluated the antifungal action of different agents over microwave-cured acrylic resin without polishing specimens previously contaminated with Candida albicans. MATERIAL AND METHODS: Sixty specimens were immersed in BHI broth previously inoculated with the yeast and stored for 3 h at 37ºC. They were divided into 5 experimental groups (n=10): G1: 2 percent chlorhexidine solution (10 min); G2: 0.5 percent sodium hypochlorite (10 min); G3: modified sodium hypochlorite (10 min); G4: effervescent agent (5 min); G5: hydrogen peroxide 10v (30 min). The specimens of the control group 1 (C1) were not disinfected. Ten additional specimens of the control group 2 (C2) were not infected with the yeast, aiming to check the asepsis during the experiment. The disinfection agents were neutralized and the acrylic resin specimens were immersed in BHI Broth for 24 h. Culture media turbidity was evaluated spectrophotometrically according to the transmittance degree, i.e. the higher the transmittance the stronger the antimicrobial action. Statistical analysis was performed (Kruskal-Wallis Test, p<0.05). RESULTS: The results, represented by the medians, were: G1 = 40; G2 = 100; G3 = 100; G4 = 90; G5 = 100; C1 = 40; C2 = 100. CONCLUSIONS: This in vitro study suggested that sodium hypochlorite-based substances and hydrogen peroxide are more efficient disinfectants against C. albicans than 2 percent chlorhexidine solution and the effervescent agent.


Subject(s)
Humans , Acrylic Resins/radiation effects , Antifungal Agents/pharmacology , Dental Disinfectants/pharmacology , Dental Materials/radiation effects , Microwaves , Acrylic Resins/chemistry , Anti-Infective Agents, Local/pharmacology , Candida albicans/drug effects , Candida albicans/growth & development , Chlorhexidine/pharmacology , Dental Materials/chemistry , Denture Cleansers/pharmacology , Ethanol/pharmacology , Hydrogen Peroxide/pharmacology , Materials Testing , Oxidants/pharmacology , Spectrophotometry , Surface Properties , Sodium Hypochlorite/pharmacology , Temperature , Time Factors
13.
J. appl. oral sci ; 17(5): 446-450, Sept.-Oct. 2009. ilus, tab
Article in English | LILACS | ID: lil-531395

ABSTRACT

The light-curing technique is relevant to reduce the degree of polymerization shrinkage, improving clinical and esthetic success of composite resin restorations. OBJECTIVE: To evaluate in vitro the effect of four light-curing techniques on depth of cure of a composite resin. MATERIAL AND METHODS: Ten specimens of a composite resin were made in cylindrical cavities prepared in PVC plates (3.0 X 7.0 mm) for each light-curing technique. Four photoactivation methods were investigated: stepped, ramped, pulse-delay and traditional. Specimens were longitudinally sectioned and polished for microhardness measurements (kg/mm²), which were made at 0.1, 1.0, 2.0 and 4.0 mm from the irradiated surface. Data were subjected to ANOVA and Tukey's test. RESULTS: The effect of factors studied (curing method and distance from the surface) and the interaction of these factors was statistically significant (p<0.05). The traditional method of cure provided higher microhardness values (69.6 ± 2.5) than the stepped (63.5 ± 3.1) and pulsed (63.9 ± 3.2) methods at all depths evaluated, but it did not differ from the ramped method (66.7± 4.4) at 0.1 and 1.0 mm of depth. CONCLUSION: All techniques employed provided satisfactory cure of the composite resin up to the depth of 2.0 mm from the irradiated surface.


Subject(s)
Humans , Composite Resins/chemistry , Dental Materials/chemistry , Composite Resins/radiation effects , Curing Lights, Dental/classification , Dental Materials/radiation effects , Hardness , Light , Materials Testing , Polymers/chemistry , Polymers/radiation effects , Radiation Dosage , Surface Properties , Time Factors
14.
Article in English | IMSEAR | ID: sea-139739

ABSTRACT

Aim: To evaluate the influence of quartz tungsten halogen and plasma arc curing (PAC) lights on Knoop hardness and change in polymerization temperature of resin composite. Materials and Methods: Filtek Z250 and Esthet X composites were used in the shade A3. The temperature increase was registered with Type-k thermocouple connected to a digital thermometer (Iopetherm 46). A self-cured polymerized acrylic resin base was built in order to guide the thermocouple and to support the dentin disk of 1.0 mm thickness obtained from bovine tooth. On the acrylic resin base, elastomer mold of 2.0 mm was adapted. The temperature increase was measured after composite light curing. After 24 h, the specimens were submitted to Knoop hardness test (HMV-2000, Shimadzu, Tokyo, Japan). Data were submitted to ANOVA and Tukey's test (a = 0.05). Results: For both composites, there were no significant differences (P > 0.05) in the top surface hardness; however, PAC promoted statistically lower (P < 0.05) Knoop hardness number values in the bottom. The mean temperature increase showed no significant statistical differences (P > 0.05). Conclusion: The standardized radiant exposure showed no influence on the temperature increase of the composite, however, showed significant effect on hardness values.


Subject(s)
Analysis of Variance , Animals , Cattle , Composite Resins/chemistry , Composite Resins/radiation effects , Curing Lights, Dental/classification , Curing Lights, Dental/standards , Dental Enamel/drug effects , Dental Materials/chemistry , Dental Materials/radiation effects , Dental Restoration, Permanent/standards , Hardness/radiation effects , Hot Temperature , Light-Curing of Dental Adhesives/methods , Reference Values , Statistics, Nonparametric
15.
Article in English | IMSEAR | ID: sea-139736

ABSTRACT

Background : Microwave postpolymerization has been suggested as a method to improve the flexural strength of an autopolymerizing denture reline resin. However, the effect of microwave postpolymerization on the residual monomer content and its influence on flexural strength have not been investigated. Objectives : This study analyzed the effect of microwave postpolymerization on the residual monomer content and its influence on the flexural strength of an autopolymerizing reline resin (Denture Liner). Materials and Methods : A total of 70 specimens (64 Χ 10 Χ 3.3 mm) were polymerized according to the manufacturer's instructions and divided into 7 groups (n = 10). Control group specimens were not subjectedto any further processing. Before testing, the specimens were subjected to postpolymerization in a microwave oven using different power (550 and 650 W) and time (3, 4, and 5 min) settings. Two specimens of each group were then manually ground into fine powder and samples extracted from the specimens using reflux method. The samples were then subjected to gas chromatography for residual monomer determination in area%. Eight specimens were subjected to a three-point bending device with a span of 50 mm and crosshead speed of 5 mm/min, and the flexural strength was determined in MPa. Data analyses included Student's t-test and one-way analysis of variance. Results : For the Denture Liner reline resin, the residual monomer content decreased and the flexural strength increased significantly with the application of microwave irradiation using different time/power combinations. The specimens with the lowest residual monomer content were the similar specimens which presented with the highest flexural strength. Conclusion : Microwave postpolymerization irradiation can be an effective method for increasing the flexural strength of denture liner (at 650 W for 5 min) by reducing the residual monomer content by further polymerization at free radical sites.


Subject(s)
Acrylic Resins/chemistry , Acrylic Resins/radiation effects , Analysis of Variance , Dental Materials/chemistry , Dental Materials/radiation effects , Denture Liners , Denture Rebasing , Methacrylates/chemistry , Methacrylates/radiation effects , Microwaves , Pliability/radiation effects , Statistics, Nonparametric
16.
Article in English | IMSEAR | ID: sea-139706

ABSTRACT

Background: Class II composite restorations are more frequently being placed with margins apical to the cementoenamel junction (CEJ) and margins within the dentin are prone to microleakage. Aims: This in vitro study was used to evaluate the influence of flowable composite and flowable compomer as gingival liner on microleakage in Class II composite restorations and compare a light-emitting diode (LED) unit with a quartz tungsten halogen (QTH) unit for light-activating composite resins. Materials and Methods: Mesioocclusal and distoocclusal Class II cavity preparations were made in 72 sound extracted premolars. The buccolingual width was 2.5 mm and the gingival margins of all the cavities were placed 1.0 mm apical to the CEJ. The boxes were prepared 1.5 mm deep axially, making 144 slot cavities. Teeth were randomly divided into the following two groups (n = 72): (I) Universal Filtek Supreme XT; Universal Filtek Supreme XT + Flwable Filtek XT and Universal Filtek Supreme XT + Dyract Flow and (II) Filtek Z250; Filtek Z250 + Flwable Filtek XT and Filtek Z250 + Dyract Flow. Flowable materials were injected into the gingival floor of the cavity to a thickness of 1.0 mm. Each increment was cured for 20 s. One-half of the subgroups in each group were cured with QTH and the other half with LED light curing units (LCUs). After 1 week of incubation at 37°C, the specimens were thermocycled (5-55°C, x1500), immersed in 0.5% basic fuchsine dye for 24 h and sectioned and microleakage was evaluated at the gingival margin by two examiners using a 0-3 score scale. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: The groups utilizing flowable liners had significantly less microleakage (P < 0.05). No significant difference was identified between Universal Filtek Supreme XT and Filtek Z250 composites with and without flowable materials. There was no significant between utilizing flowable composite or flowable compomer and between each similar subgroup when polymerized with either the LED or the QTH LCUs. Conclusions: A layer of flowable materials at the gingival floor of Class II composite restorations may be recommended to improve the marginal seal of a restoration.


Subject(s)
Coloring Agents/diagnosis , Compomers/chemistry , Compomers/radiation effects , Composite Resins/chemistry , Composite Resins/radiation effects , Curing Lights, Dental/classification , Dental Cavity Lining/methods , Dental Cavity Preparation/classification , Dental Leakage/classification , Dental Materials/chemistry , Dental Materials/radiation effects , Dental Restoration, Permanent/classification , Humans , Materials Testing , Rosaniline Dyes/diagnosis , Temperature , Time Factors , Tooth Cervix/pathology
17.
Braz. dent. j ; 20(4): 319-324, 2009. tab, ilus, graf
Article in English | LILACS | ID: lil-536322

ABSTRACT

The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5 percent). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.


Este estudo comparou a contração de polimerização de resinas compostas fotoativadas por luz halógena (QTH) e diodo emissor de luz (LED). Foram confeccionados bastões de vidro (5,0 mm x 5,0 cm), e uma de suas extremidades sofreu jateamento com óxido de alumínio, sobre a qual foi aplicado um adesivo e fotoativado com luz halógena. Os bastões de vidro foram acoplados verticalmente, em pares, em uma máquina universal de ensaios (EMIC DL-2000) e as resinas compostas aplicadas no bastão inferior. A distância entre os bastões foi padronizada em 2 mm e um extensômetro foi acoplado a eles. As resinas foram fotoativadas (n=20), sendo 10 por QTH e 10 por LED utilizando dois aparelhos posicionados em lados opostos, acionados simultaneamente por 40 s. A tensão de contração foi analisada em dois momentos: logo após a polimerização (t40s) e 10 min após (t10min). A tensão de contração apresentada por todas as resinas foi maior em t10min do que em t40s, independente da fonte ativadora. A resina de micropartículas apresentou menores valores de tensão de contração com valores estatisticamente significantes em relação às demais resinas. Para as resinas híbrida e microhíbrida não houve influência da unidade ativadora sobre a tensão de contração, com exceção para a resina de micropartículas em t10min. Concluiu-se que a composição da resina composta foi o fator que mais interferiu na tensão de contração da resina composta.


Subject(s)
Composite Resins/radiation effects , Curing Lights, Dental/classification , Light-Curing of Dental Adhesives/methods , Dental Materials/radiation effects , Analysis of Variance , Acrylic Resins/chemistry , Acrylic Resins/radiation effects , Composite Resins/chemistry , Dental Stress Analysis , Dental Materials/chemistry , Dentin-Bonding Agents/chemistry , Dentin-Bonding Agents/radiation effects , Materials Testing , Nanoparticles/chemistry , Nanoparticles/radiation effects , Polyurethanes/chemistry , Polyurethanes/radiation effects , Resin Cements/chemistry , Resin Cements/radiation effects , Statistics, Nonparametric
18.
Braz. j. oral sci ; 7(25): 1555-1558, Apr.-June 2008. tab, graf
Article in English | LILACS, BBO | ID: lil-521314

ABSTRACT

Aim: This study aimed to evaluate the flexural strength and flexural modulus of different resin composites (MasterFill, Opallis, Z250, Supreme) after photoactivation with quartz-tungsten-halogen (QTH - XL2500) or light-emitting diode (LED - Radii and Ultrablue Is) light-curing units (LCUs). Methods: The irradiance and spectral emission of each unit were evaluated using a power meter and a spectrometer. Flexural strength (MPa) was determined in a three-point bending test in accordance with the ISO4049 standard specifications. Flexural modulus (GPa) was measured from the linear-elastic range on the stress-deformation profile. Data were submitted to two-way ANOVA and Tukey’s test (p<0.05). Results: Different values for irradiance (850, 780 and 590 mW/cm2) and peak of emission (484, 456, 467 nm) were detected for XL2500, Radii and Ultrablue Is, respectively. Flexural strength and modulus were dependent on both material and LCU. Among the resins, Z250 and Supreme showed significantly higher strength and modulus than MasterFill and Opallis. Comparing the LCUs, Ultrablue Is showed significantly lower flexural strength and modulus than the others. Conclusion: Flexural strength and modulus were dependent on the irradiance and the spectral emission of the curing units, as well on the resin composite tested.


Subject(s)
Composite Resins , Light , Dental Materials/radiation effects , Dental Materials/chemistry , Physical Phenomena , Polymers , Technology, Dental/instrumentation
19.
J. appl. oral sci ; 16(1): 35-42, Jan.-Feb. 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-472687

ABSTRACT

The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used were Z100, A110, SureFil and Bisfil 2B (chemical-cured). Composite deformation upon polymerization was measured by the strain gauge method. The shrinkage stress was measured by photoelastic analysis. The polymerization shrinkage data were analyzed statistically using two-way ANOVA and Tukey test (p<0.05), and the stress data were analyzed by one-way ANOVA and Tukey's test (p<0.05). Shrinkage and stress means of Bisfil 2B were statistically significant lower than those of Z100, A110 and SureFil. In general, the PD mode reduced the contraction and the stress values when compared to CM. LED generated the same stress as QTH in conventional mode. Regardless of the activation mode, SureFil produced lower contraction and stress values than the other light-cured resins. Conversely, Z100 and A110 produced the greatest contraction and stress values. As expected, the chemically cured resin generated lower shrinkage and stress than the light-cured resins. In conclusion, The PD mode effectively decreased contraction stress for Z100 and A110. Development of stress in light-cured resins depended on the shrinkage value.


Subject(s)
Humans , Composite Resins/chemistry , Curing Lights, Dental/classification , Dental Materials/chemistry , Chemical Phenomena , Composite Resins/radiation effects , Models, Dental , Dental Cavity Preparation/classification , Dental Materials/radiation effects , Epoxy Resins/chemistry , Materials Testing , Polymers/chemistry , Polymers/radiation effects , Radiation Dosage , Resin Cements/chemistry , Stress, Mechanical , Surface Properties , Silicon Dioxide/chemistry , Silicon Dioxide/radiation effects , Time Factors , Zirconium/chemistry , Zirconium/radiation effects
SELECTION OF CITATIONS